Lincoln Electric FineLine 170HD Operator's Manual page 94

Table of Contents

Advertisement

FineLine 170HD Plasma System
BK8053-000111 Rev D
Remove the drain hose, reinsert the valve plug, close the valve, and clean up
any leaked coolant. Note: On older Systems, reconnect the pump inlet hose
and clean up any leaked coolant.
Unscrew the coolant filter housing and remove the coolant filter. Install a new
coolant filter and replace the coolant filter housing. Clean up any leaked
coolant.
Reconnect the coolant supply hose on the rear of the Power Supply and clean
up any leaked coolant.
Discard old coolant and filter housing according to national and local codes.
Follow all of the steps in Section 3.19 "Fill the Cooling System" to complete
this procedure.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.