FineLine 170HD Plasma System
Source FL3HD
Event Code
4194304
8388608
33554432
67108864
536870912
1073741824
2147483648
4294967296
8589934592
17179869184
137438953472
274877906944
549755813888
1099511627776
2199023255552
9223372036854770000
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Status
Description
Light
814
Cooler Flow Fault
815
Cooler Level Fault
Switchboard Thermistor
825
Not Connected
Switchboard A Thermal
751
Error
64
Safety Circuit Not Ready
299
N2 Over Pressure
299
O2 Over Pressure
299
H17 Over Pressure
299
Air Over Pressure
299
Argon Over Pressure
492
Gas MUX Missing
491
CAN Fault
45
Secondary Over Voltage
826
High Coolant Flow
827
Flow without Active Pump
Other
Power Source Fault
Page 104 of 132
BK8053-000111 Rev D
Possible Resolution
1) Check that the machine is
supplied 3 phase input.
2) Check for blockage of coolant
supply hose and coolant return
hose.
3) Check for blockage of torch leads.
4) Check coolant pump operation.
5) Check the coolant filter cartridge
and replace if dirty.
1) Check for coolant leaking from
supply and return hoses, ASC, torch
leads, and torch connections.
2) Add coolant to the reservoir until it
reaches the bottom neck of the
reservoir.
Check that the thermistor is plugged
into each switchboard.
1) Check for blockage of the inlet
and outlet vents to the power
sections.
2) Check that power section fans are
operating properly.
EStop activated.
Adjust gas regulator until pressure is
within specifications. Refer to
Section 2.6.
Check wiring between control board
and gas mux PCB.
Check the Power Supply
interconnect cable.
Report issue to Lincoln Electric
service department.
Verify all consumables are installed.
Read the error conde blinking on the
front of the Power Supply and report
the fault to Lincoln Electric service
department for assistance.

Advertisement

Table of Contents
loading