FineLine 170HD Plasma System
4.4.5 Settings > Gas Controller
I-CTP: When enabled (
sensing) output logic is inverted – output turns off upon sensing the plate (refer to
Section 3.16).
I-TAC: When enabled (
inverted – output is off when arc is on (refer to Section 3.16).
Arc Hold: When enabled (
CTP functions are initiated as normal, but an arc is not initiated. Arc Hold is released
by removing the Start Command and reasserting – the Start Command must be
removed for a minimum of 10ms before reasserting. Upon reasserting the Start
Command, the arc will be initiated.
The Arc Hold feature can only be used with DES (refer to Section 4.2.4).
Time To Start (TTS) is the length of time in milliseconds (ms), upon removal of the
Start Command, after which the System will revert to the ready state if the Start
Command has not been reasserted. The Start Command must be reasserted within
9.5 seconds of initial receipt otherwise the System will revert to the ready state.
Removal of the Start Command after reasserting (releasing arc hold) will terminate
the arc and return System to ready state.
Auto-CTP: When enabled (
and disables when Start Signal received (cutting). This avoids the need for the
Motion Controller to post CTP enable/disable commands through CutLinc to the Gas
Controller.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
), the CNC Plate Sense (a.k.a., Clear-the-Plate or Ohmic
), the CNC Transferred Arc Circuit (TAC) output logic is
), upon initial receipt of Start Command, preflow and
), automatically enables CTP when idle (not cutting)
Page 78 of 132
BK8053-000111 Rev D