8.2.2.6

Alarm Setting

In the Alarm Setting window, click Add to insert and set new alarm setting, click Delete to remove the
selected alarm setting, click OK to exit and save the setting, Cancel to exit without saving, and Default to
revert back to original factory settings.
(1)
(2)
(3)
(4)
(5)
To set the Alarm Setting:
1. Click Add to insert and set a new alarm setting. Click the items in the (7) Alarm Setting List, if you want
to modify the alarm setting.
2. In (1) Alarm Setting number/Name/Description, display the selected alarm setting number in the list
below. Enter alarm name and description.
3. In (2) Enable Time, the number from 00 to 23 represent the time in 24-hour clock. Select the time and
click the block you want to enable or disable the alarm function. When it is "disable" the color of the block
turns white.
4. In (3) Conditions, you can set "Trigger if any" to activate if it falls to one of the conditions or "Trigger if
all" to activate if it falls to all conditions.
- In Camera section, select and click on the camera number in Motion Detected and Video Loss to
set the condition for the system to alarm.
- In Missing and Suspicious Object/Scene, click the camera number and select the certain object on
the screen (right click on camera number for detailed setting)), and when the certain object is missing
or doubtful, the system will alarm. (see also
been moved, the system will alarm, too.
- In Audio Detection, click the camera number to the system to alarm when detect the abnormal
voice.
5. In (4) Sensor, select and click on the sensor number (use  and  to select the sensor) to set the
condition for the system to alarm. If the sensor normal status is high, set the sensor condition to low.
- Continue trigger duration: Set a time period that when sensor has been trigger and stay in the
same status for that period, then the alarm will be sent out.
- Abnormal Event: Enable/disable to set the condition of the event for system to alarm..
(6)
Chapter
4.9.11) In Scene Change, when the camera has
161