Adjusting The Tray Upper Surface Detection Position - Konica Minolta bizhub 500 Service Manual

Hide thumbs Also See for bizhub 500:
Table of Contents

Advertisement

Field Service Ver1.0 Feb.2006
3.5

Adjusting the tray upper surface detection position

This adjustment is made when replacing the FS control board (FSCB), or the main tray upper limit LED (LED19)
or the main tray upper limit sensor (PS19).
A. Procedure
[1]
[2]
1.
2.
4521f3c011na
3.
[4]
[3]
4521f3c012na
3. MECHANICAL ADJUSTMENT
Set the output check mode "Sensor output check
mode."
(See P.17)
Rotate VR1 [1] provided on the FS control board
(FSCB) up to the limit counterclockwise.
Place the paper [3] on the main tray [2] to block
the light of the main tray upper limit LED (LED19)
[4].
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 420

Table of Contents