Field Service Ver1.0 Feb.2006
[3]
[1]
[2]
[4]
[1]
50gaf2c048na
Note
• When installing the cleaning blade assy [1], be
sure to insert the transparent sheet section
[2] of the unit the between the collection
screw [3] and the collection paddle [4].
8.
Reinstall the above parts following the removal
steps in reverse.
3. PERIODIC CHECK
43