Uc 200 Maintenance; Replacing An Air Filter - Siemens SICHARGE UC 100 Operating Instructions Manual

Table of Contents

Advertisement

5. Unscrew the fastening screws of the cabinet fan
6. Pull out cabinet fan
7. Disconnect the connecting cables of the fan
Install a new cabinet fan
1. Connect the connecting cables of the fan
2. Insert cabinet fan
3. Tighten the fastening screws of the cabinet fan
4. Insert the fabric filter into the filter holder
5. Plug in the filter grille
6. Mount fan cover
7. Tighten the fastening screws of the fan cover
10.6

UC 200 maintenance

10.6.1

Replacing an air filter

The air filters of the charging station remove the dust from the outside air pulled in for cooling
the interior. With increasing operating time, the filtered dust particles reduce the air flow
through the filters. The reduced airflow cools the interior of the charging station less. This causes
the temperature inside the charging station to rise.
To keep the air inside the charging station within the permitted temperature range, regularly
replace the fabric filters of the cabinet fans.
Required tools and spare parts
You will need the following tools to replace an air filter:
• Screwdriver
• Bit: Hexagon socket, SW6
You will also need the following spare part:
• 3 Fabric filter: Filter class G3 according to standard EN 779, dimensions: 223 x 223 mm
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800
Operating Instructions, 10/2022, A5E50828019-AC
Maintenance and service
10.6 UC 200 maintenance
161

Advertisement

Table of Contents
loading

Table of Contents