Checking Recorded Alarms - Siemens SICHARGE UC 100 Operating Instructions Manual

Table of Contents

Advertisement

Operating
8.8 Operating the Service menu
Selecting options
Use the option buttons to select the following option:
Button
Alarm
Charger Info
Set Language
Energy Meter
Graphics
8.8.2

Checking recorded alarms

When the charging station triggers an alarm due to an unwanted operating state, the charging
station immediately stops charging. The touch screen of the charging station displays an alarm
message in full screen mode or the alarm button in the menu.
Requirements
• You have opened the Options menu.
• You have pressed the "Alarm" button in the Options menu.
132
Option
The touch screen displays the "Alarm history" menu. The menu contains
a list of all the recorded alarms of the charging station.
The touch screen switches to the "Charger Info" menu. In the menu, the
touch screen shows you the current voltage and current values of the
charging station's power supply. In the "Charger Info" menu, you can also
find the current values of the voltage at the DC output, the frequency and
the charging status.
The touch screen displays the "Set Language" menu. In the menu, you
select the user language of the Human Machine Interface (HMI).
The touch screen displays the "Energy Meter" menu. In the menu, you
can see the start and end date of the charging process, the charge status
at the start and end, the energy transferred and an alarm code.
The touch screen displays the "Graphics" menu. In the menu, the touch
screen displays the course of the charging voltage and charging current
during the charging process in a diagram.
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800
Operating Instructions, 10/2022, A5E50828019-AC