Securing an electrical system before starting work
Before starting work on and in electrical installations, apply the following five safety rules:
1. Disconnect
2. Secure against reclosing
3. Ensure there is no voltage present
4. Ground and short-circuit
5. Cover or shield adjacent live parts
Prepare to switch on again after work is finished
After finishing and checking the work, prepare the restart as follows:
• Inform persons no longer required that the work is completed and no further work is
permitted
• Withdraw persons no longer required
• Remove all tools, equipment and aids used
Switch on the electrical system again
After finishing the work, remove the protective measures and switch the system on again:
1. Remove short-circuit
2. Remove grounding
3. Remove covers or barriers
4. Remove fuse to prevent restart
5. Switch the system back on
2.3
Emergency Stop button
In a hazardous situation, pressing the Emergency Stop button immediately puts the charging
station into a safe emergency stop state.
SICHARGE UC 100, UC 200, UC 300, UC 400, UC 600, UC 800
Operating Instructions, 10/2022, A5E50828019-AC
Safety information
2.3 Emergency Stop button
13