Konica Minolta bizhub C658 Service Manual page 1566

Hide thumbs Also See for bizhub C658:
Table of Contents

Advertisement

bizhub C658/C558/C458/C368/C308/C258
Error code
CFD0B
CFD0C
CFD0D
CFD0E
CFD0F
6.17.2  CFD1# (bizhub C658/C558/C458)
Error code
CFD10
CFD11
CFD12
CFD13
CFD14
CFD15
CFD16
CFD17
CFD18
CFD19
CFD1A
CFD1B
CFD1C
CFD1D
CFD1E
CFD1F
6.17.3  CFD2# (bizhub C658/C558/C458)
Error code
CFD20
CFD21
CFD22
CFD23
CFD24
CFD25
CFD26
CFD27
Dual scan image processing board (Asic2014) LCD output interface
had underrun
Dual scan image processing board (Asic2014) JBIG core detected
unknown marker
Dual scan image processing board (Asic2014) JBIG core detected SC
count overflow
Dual scan image processing board (Asic2014) image output interface
(DMA23) had underrun
Dual scan image processing board (Asic2014) image input interface
(DMA16) had overflow
SDTMDT is accessed during dual scan image processing board
(Asic2014) soft reset active
DMA04 (table) is accessed during dual scan image processing board
(Asic2014) soft reset active
DMA13 (FAX debug) is accessed during dual scan image processing
board (Asic2014) soft reset active
SDTAAA is accessed during dual scan image processing board
(Asic2014) soft reset active
A time out error is received on the dual scan image processing board
(Asic2014) SDTMDT.
A time out error is received on the dual scan image processing board
(Asic2014) SDTAAA.
An access lock error is received on the dual scan image processing
board (Asic2014) SDTAAA.
An failed access to the invalid field of the sub CPU is received via the
dual scan image processing board (Asic2014) SDTAAA.
An overflow detected in dual scan image processing board (Asic2014)
DMA14 mdt_ctr_14o
Compression data size over detected during dual scan image
processing board (Asic2014) DMA14 JPEG compression
Dual scan image processing board (Asic2014) DMA14 EOI yet to be
detected
The CMM table of DMA14 is accessed during dual scan image
processing board (Asic2014) soft reset active
The JPEG core slave space of DMA14 is accessed during dual scan
image processing board (Asic2014) soft reset active
The comment table of DMA14 is accessed during dual scan image
processing board (Asic2014) soft reset active
An overflow detected in dual scan image processing board (Asic2014)
DMA15 mdt_ctr_15o
Compression data size over detected during dual scan image
processing board (Asic2014) DMA15 JPEG compression
Dual scan image processing board (Asic2014) DMA15 EOI yet to be
detected
The CMM table of DMA15 is accessed during dual scan image
processing board (Asic2014) soft reset active
The JPEG core slave space of DMA15 is accessed during dual scan
image processing board (Asic2014) soft reset active
The comment table of DMA15 is accessed during dual scan image
processing board (Asic2014) soft reset active
Completer Abort exists in dual scan image processing board
(Asic2014) memory master access
Unsupported Request exists in dual scan image processing board
(Asic2014) memory master access
Completion Timeout exists in dual scan image processing board
(Asic2014) memory master access
Poisoned TLP exists in dual scan image processing board (Asic2014)
memory master access
Item
Item
Item
K-238
K TROUBLESHOOTING > 6. ABORT CODE
Component
Component
Dual scan image
processing board (DSIPB)
Component
Dual scan image
processing board (DSIPB)
Rank
Rank
C
Rank
C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents