Connecting The Server To The Elan Subnet - Nortel CallPilot Installation Manual

Nortel callpilot: install guide
Hide thumbs Also See for CallPilot:
Table of Contents

Advertisement

What is next?
Continue with

Connecting the server to the ELAN subnet

Introduction
Connect the CallPilot server to the Meridian 1 switch or CS 1000 system
using the ELAN subnet.
For important considerations about using the ELAN subnet in your network, see
the Planning and Engineering Guide (NN44200-200).
To comply with EMC radiation requirements, a Class A Ethernet switch or hub
must be located 10 m (33 ft.) away from the 1005r server. You must use shielded
Ethernet cables.
To connect the server to the ELAN subnet
Step
1
2
3
Copyright © 2007, Nortel Networks
.
"Connecting the server to the ELAN subnet" (page
Note: If you are installing a High Availability system, do not connect
either sever to the ELAN subnet. The connection to the ELAN subnet is
made when you configure the system.
Action
See the diagram on page
locate the ELAN Ethernet connector.
Connect an RJ-45 network cable from the ELAN Ethernet switch or
hub to the ELAN connector on the server.
Note: The ELAN Ethernet switch or hub is optional if you use
a cross-over network cable to make a direct point-to-point
connection from the server to the switch. However, if you choose
to establish a direct point-to-point ELAN connection, no other
device can connect to the ELAN subnet.
At the switch, connect the ELAN network cable to the ELAN Ethernet
interface. Complete the connection from the transceiver to the
switch.
Nortel CallPilot
1005r Server Hardware Installation
NN44200-308 01.04 Standard
5.0 30 April 2007
Connecting the server to the ELAN subnet 35
ATTENTION
ATTENTION
"Rear panel connectors" (page 31)
35).
to

Advertisement

Table of Contents
loading

This manual is also suitable for:

Callpilot 1005r

Table of Contents