36 Chapter 4 Installing the server and peripheral devices
What is next?
IF the server is
connected to a Nortel server subnet
not connected to a Nortel server
subnet

Connecting the server to the Nortel server subnet (optional)

Introduction
This section provides instructions to connect the server to the Nortel server
subnet.
To comply with EMC radiation requirements, a Class A Ethernet switch or hub
must be located 10 m (33 ft.) away from the 1005r server. Shielded Ethernet
cables must be used.
To connect the server to the Nortel server subnet
Step
1
Copyright © 2007, Nortel Networks
.
DANGER
Risk of fire hazard
Do not install a Media Access Unit (MAU) in ducts,
plenums, or other spaces used for environmental air. Do
not install a MAU above a false ceiling or below a raised
floor, unless you can confirm that these spaces are not
used to convey environmental air.
Note 1: The Nortel server subnet is optional. However, it is required to
support desktop and Web messaging users.
Note 2: If you are installing a High Availability system, do not connect
either sever to the Nortel Server Subnet. The connection to the Nortel
Server Subnet is made when you configure the system.
Action
See the diagram on page
locate the CLAN connection.
Nortel CallPilot
1005r Server Hardware Installation
NN44200-308 01.04 Standard
5.0 30 April 2007
—End—
THEN
continue with
to the Nortel server subnet (optional)"
(page
36).
continue with installing the software
feature dongle. See
Nortel software feature dongle" (page
37).
ATTENTION
"Rear panel connectors" (page 31)
"Connecting the server
"Installing the
to

Advertisement