Remove A Ptx10004 Routing And Control Board - Juniper PTX10004 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX10004:
Table of Contents

Advertisement

Power Requirements for PTX10004 Components | 89
PTX10004 Routing and Control Board LEDs | 65

Remove a PTX10004 Routing and Control Board

In redundant configurations, a PTX10004 RCB is a hot-removable and hot-insertable field-replaceable
unit (FRU). In base configurations, you need to install a second RCB before removing a failing RCB to
prevent the router from shutting down. We recommend that you take base systems offline before replacing
the RCB.
Before you remove an RCB, ensure that you have an electrostatic discharge (ESD) grounding strap.
CAUTION:
down. In redundant configurations, removal of the RCB causes the system to reboot
and start the election process for a new primary.
To remove an RCB:
1. Place an antistatic bag or antistatic mat on a flat, stable surface.
2. Use the following CLI commands to take the RCB offline (re0 or re1).
user@host> request node power-off re0|re1
Power-off the node ? [yes,no?]
yes
user@host> request chassis cb slot slot-number offline
Offline initiated
You can use the show chassis environment cb | match State CLI command to verify that the RCB is
offline.
user@host0> show chassis environment cb | match State
State
State
In base configurations, removal of the RCB causes the system to shut
Online Master
Offline Standby
164

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptx10004-base3Ptx10004-prem2Ptx10004-prem3

Table of Contents