Level
Occurred
-------------------------------------------
Minor
35
Major
3
Fatal
0

PTX10004 Chassis Alarm Messages

Chassis alarms indicate a failure of the device or one of its components. Chassis alarms are preset and
cannot be modified.
Chassis alarms on PTX1004 modular chassis have two severity levels:
Major (red)—Indicates a critical situation on the device that has resulted from one of the conditions
described in
Table 55 on page
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left unchecked, might
cause an interruption in service or degradation in performance. A yellow alarm condition requires
monitoring or maintenance.
Table 55 on page 242
describes the chassis alarm messages on a PTX10004 router.
Table 55: Chassis Component Alarm Conditions on the PTX10004
Chassis
Component
Alarm Condition
Routing
An RCB has failed.
Control
An RCB has been removed.
Board
Line cards
A line card is offline.
A line card has failed.
A line card has been removed.
Cleared
Action-Taken
32
0
0
242. A red alarm condition requires immediate action.
39
6
0
Alarm Severity
Remedy
Major (red)
Replace the failed RCB.
Minor (yellow)
Install an RCB in the empty slot.
Minor (yellow)
Check the line card. Remove and
reinstall the line card. If this fails,
replace the failed card.
Major (red)
Replace the failed line card.
Major (red)
Install a line card in the empty slot.