Frame Relay Options (Fr Opts); Signal Type (Signal); T391; N391 - ADTRAN TSU IQ+ User Manual

T1 frame relay performance monitoring tsu with v.35 and dsx-1 ports
Table of Contents

Advertisement

Chapter 7. Configuring the Network Port

Frame Relay Options (FR OPTS)

The following selections are available when F
is selected from the N

Signal Type (SIGNAL)

Set the signaling type option to match the network signaling type.
A
the attached frame relay DTE. If A
DTE device attached, the TSU IQ+ uses ANSI T1.617-D signaling
type.
Choices: N
ITU-T Q.933-A (Annex A), or A

T391

Set the time (in seconds) between polls to the frame relay network.
Range: 5 to 30 seconds.

N391

Determine how many link integrity polls occur in between full
status polls.
Range: 1 to 255.

N392 and N393

These parameters define the error threshold for the UNI formed by
the TSU IQ+
threshold is met, the signaling state status is changed to down,
which indicates a service-affecting condition. This condition is
cleared once N393 consecutive error-free events are received. N392
defines the number of errors required in a given event window,
while N393 defines the number of polling events in each window.
For example:
If N392=3 and N393= 4, then if three errors occur within any four
events the interface is determined inactive.
7-4
mode forces the TSU IQ+ to use the same signaling type as
UTO
, LMI (gang of four), ANSI T1.617-D (Annex D),
ONE
Network
TSU IQ+ User Manual
P
C
ETWORK
ORT
ONFIGURATION
is selected and there is no
UTO
.
UTO
port and the frame relay switch. If the error
R
O
RAME
ELAY
PTIONS
menu: