Frames In

Total received frames since the unit went into dial backup mode (or
since last reset).

Frames Out

Total transmitted frames since the unit went into dial backup mode
(or since last reset).

Errored Frames

Total errored frames received since the unit went into dial backup
mode (or since last reset).

CRC Errors

Number of frames received on the dial backup circuit with CRC
violations.

Abort Frames

Total frames received on the dial backup circuit without a closing
flag.

Octet Align

Number of frames received on the dial backup circuit with a bit
count that does not fall on 8-bit boundaries.

System Statistics Available on Front Panel

Select S
and checksum. This screen is shown in Figure 10-14. Press
return to the S
61200275L1-1
from the S
menu to display the software version
YS
TATS
menu.
TATS
VERSION CHKSUM
VER 2.200

Figure 10-14. System Statistics Screen