Chapter 11. Testing

PVC Loopback

A PVC L
PVC. During this test, the TSU IQ+ periodically sends test frames to
the remote TSU IQ+ which are then returned for analysis. The
bandwidth required is approximately 1 kbps for each PVC in test.
See Figure 11-3 for the terminal menu.
DLCI <0 = All> (DLCI)
Enter the DLCI of the PVC to be tested (or enter 0 to test all
available PVCs). Range is 0 to 1007.

Test Length

Amount of time (in minutes) that you want the test to take place.
Enter 0 for a continuous test. This option is not available on the
front panel. Range is 0 to 1440.

Start Test

Starts the test.
11-4
test is a non-intrusive loopback option for each
OOPBACK
TSU IQ+ User Manual

Figure 11-3. PVC Loopback Menu