Stop Test; View Test; Pvc Active/Inactive/Undefined; Test Active/No Test Active - ADTRAN TSU IQ+ User Manual

T1 frame relay performance monitoring tsu with v.35 and dsx-1 ports
Table of Contents

Advertisement

Stop Test

Ends the test in progress prematurely or terminates a continuous
test.

View Test

Displays the T
11-6. Descriptions of each field in the T

PVC Active/Inactive/Undefined

Displays current state of the selected PVC as determined by the
switch.

Test Active/No Test Active

Displays current testing state of the TSU IQ+.

Frames Rx

Number of frames received on the selected PVC during the current
loopback test.

Frames Tx

Number of frames transmitted across the selected PVC during the
current loopback test.

Lost Frames

Number of frames lost in the receiving direction (traveling from the
remote TSU IQ+ to the local TSU IQ+).

Remote Lost Frames (RMT LOST FRAMES)

Number of frames lost in the transmitting direction (traveling from
the local TSU IQ+ to the remote TSU IQ+).

Minimum Loop Response Time (MIN RESP TIME)

Minimum round-trip time (in seconds) for the current test.

Maximum Loop Response Time (MAX RESP TIME)

Maximum round-trip time (in seconds) for the current test.
61200275L1-1
S
EST
TATISTICS
Active: The PVC is currently operational.
Inactive: There is currently a physical or frame relay layer
problem at the remote end of the PVC, or a problem exists
inside the frame relay cloud for the selected PVC.
Undefined: The PVC is undefined for the switch.
TSU IQ+ User Manual
menu shown in Figure 11-4 on page
S
EST
TATISTICS
Chapter 11. Testing
menu follow.
11-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

1200275l1

Table of Contents