Network Port Statistics Available On Front Panel; Tsu Loop State; Pri Loop State; Dbu Status - ADTRAN TSU IQ+ User Manual

T1 frame relay performance monitoring tsu with v.35 and dsx-1 ports
Table of Contents

Advertisement

Network Port Statistics Available on Front Panel

TSU Loop State

Current state of the incoming T1 circuit.

PRI Loop State

Current state of the PRI circuit (PRI only).

DBU Status

Current state of the incoming DBU circuit.

Signal State

Current state of the

Signal State Change

Number of changes in the signaling protocol state.

Signal Timeouts

Total T391 timeouts that have occurred since the last reset.

Signal Errors

Total signal frames received with PVC signaling protocol
violations.

Frames In

Total received frames since last reset.

Frames Out

Total transmitted frames since last reset.

Errored Frames

Total errored frames received since last reset.

CRC Errors

Number of frames received with HDLC CRC violations.

Abort Frames

Total frames received without a closing flag.

Octet Align

Number of frames received with a bit count that does not fall on
8-bit boundaries.
61200275L1-1
port (up or down).
Network
TSU IQ+ User Manual
Chapter 10. Statistics
10-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

1200275l1