Port Ua Time; Line Code; Path Code; Dsx-1 Port Statistics Available On Front Panel - ADTRAN TSU IQ+ User Manual

T1 frame relay performance monitoring tsu with v.35 and dsx-1 ports
Table of Contents

Advertisement

Chapter 10. Statistics

Port UA Time

Time in seconds the network port is unavailable for data delivery.
This can mean that the T1 link is down or in test, or that the PVC
signaling state is down.

Line Code

Number of line code violations. Line code violations include BPVs
that are not part of B8ZS code or excess zero violations.

Path Code

Number of path code violations. Path code violations include
frame bit errors for D4 framing and superframes with CRC errors
for ESF framing.

DSX-1 Port Statistics Available on Front Panel

TSU Loop State

Current state of the incoming T1 circuit.

Line Code

Number of line code violations. Line code violations include BPVs
that are not part of B8ZS code or excess zero violations.
Path Code
Number of path code violations. Path code violations include
frame bit errors for D4 framing and superframes with CRC errors
for ESF framing.

DBU Port Statistics Available on Front Panel

PRI Loop State

Current state of the PRI circuit.

D Channel State

Current state of the PRI D channel (PRI only).

DBU Status

Current state of the DBU circuit (not available for PRI card). For PRI
status, see Call Manager on page 10-26.

Time in DBU

The amount of time (in seconds) that the unit has been in dial
backup mode.