7�4 CONNECTION OF EXTERNAL
THERMOSTAT
To manage the stove with an external thermostat,
connect it to the GND I02 connectors of the electronic
board as shown in the figure, disconnecting the existing
connection.
Connect an open/closed external thermostat, therefore
potential-free�
If you want to measure the room temperature through an
external thermostat (optional), you will have to activate
the reading in the specific menu�
7�5 TESTING AND COMMISSIONING
Stove start-up must be preceded by testing, which
includes an operational check of the following elements:
• connection to the smoke evacuation system;
• electrical connections;
• operation of any connected external probes;
• checking that all materials used to build the smoke
duct, chimney and chimney pot are regulation and
suitable for use.
The testing is positive only when all operational phases
have been completed without any anomaly being
detected.
20
Switch
Power plug
Fusible
GND
0 I
2

8 CONTROL PANEL

8�1 DESCRIPTION
The control panel consists of:
A) A top part with status LEDs and backlit icons that
identify each function;
B) LED display;
C) ON button
D) "Cancel" and display "error" button
E) Two arrow buttons to scroll between the various
functions
Fig. 7.1
F) Two buttons
parameters and access the submenus;
G) An enter button
settings.
D
C
All the buttons are capacitive, therefore the functions are
activated without needing to press hard on the buttons,
rather by just touching the surface�
8�2 STATUS LED
ICON
WARNING
Fig. 7.2
Failed ignition
Maintenance
Service
Remote control
receiver
Timer active
Status LED (near
the button
;
;
and
to set the operating
to confirm the parameter or the
A
B
E

DESCRIPTION

Indicates an error (see table
on page 27 for possible
causes)
Indicates the need to perform
maintenance
Indicates an error
It receives the inputs sent by
the remote control (optional)
Indicates whether the timer
function is active
LED on steady: stove on and
)
operating
LED flashing: stove in the
ignition stage or in standby
LED off: stove off
;
F