Stove Assembly

1. Glass Frame Removal

To access the firebox, use the 4 mm hex key to remove
the four socket head screws that attach the glass frame
to the firebox. See fig. 18.
• Remove the labeled lower skamol retainer from the
firebox and discard.

2. Routing the Power Supply

The power cord located in the valve compartment is
connected to the Fan Control Module which is the main
power supply for all stove operating functions. Route
the cord through the pedestal and out the rear of the
pedestal base as in fig. 18, or through the floor.
CAUTION: Take care that the pedestal base does not
pinch the power cord. You should be able to feel free
play in the cord.
The 10 foot extension power cord, supplied in the
hardware bag, is intended to connect the interior cord
to the nearest 120V house current outlet.
DO NOT CONNECT THE STOVE TO HOUSE CUR-
RENT UNTIL THE INSTALLATION IS COMPLETE AND
YOU ARE READY TO INITIATE THE FIRST BURN.
3. Connecting the Gas Supply
Gas Supply Requirements
ALL INSTALLATIONS MUST COMPLY WITH LOCAL
CODE OR IN THE ABSENCE OF LOCAL CODE, MUST
COMPLY WITH THE MOST RECENT EDITION OF THE
NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR
CAN-B149.
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GAS-FITTER WHEN INSTALLED IN
THE COMMONWEALTH OF MASSACHUSETTS.
Shut-off Valve
All codes require a gas shut-off valve (gas cock) and
union to be installed in the supply line within 6 feet of
the appliance. This allows for the disconnection of the
stove for servicing and maintenance. See Fig. 19.
A T-HANDLE GAS SHUT-OFF VALVE IS RE-
QUIRED IN MASSACHUSETTS IN COMPLIANCE
WITH CODE 248CMR.
14
Figure 18.
Glass frame
removal.
The stove and gas control valve must be discon-
nected from the gas supply piping during any pressure
testing of the system at test pressures in excess of 1/2
psig. For pressures lower than 1/2 psig, isolate the gas
supply by closing the manual shut-off valve.
Control Valve Connection
The gas supply line connection to the stove flex line
can be made at the rear of the base plate or through the
floor. The gas supply line should be a minimum 3/8"
inside diameter, or the appropriate size to provide suf-
ficient gas pressure to the valve regardless of the input
setting.
The use of flexible gas appliance connectors
is acceptable in many areas in the U.S. In Canada,
methods vary depending on local code. If local codes
permit, use flexible gas line for ease of installation and
service. For those locales where flexible gas lines are
not permitted, use the 3/8" iron fitting to make the
connection at the top side of the Control Valve. See fig.
19.
Secure all joints tightly using appropriate tools and
sealing compounds (for propane units, be sure to use
compounds that are propane resistant). Turn on gas
supply and test for gas leaks using a 50/50 soapy water
solution or a gas detector.