8�3 DESCRIPTION OF THE MENUS (OR
FUNCTION ICONS)
ICON
FUNCTION
Power
Fan
*(where featured)
Temperature
Fuel
Timer
Setup
To access the submenus:
a) Use the
buttons to go to the setup menu
to confirm;
b) Use the
button to select the password
press
to confirm;
c) Use the
button to scroll to and select submenu and press
to confirm.
ICON
FUNCTION SUBMENU
Setup
[14]
Submenus [30] , [31] and [40] in the Setup menu are password-protected and reserved for service centre personnel.
* If the pellet used produces an excessive residue in the fire pot at the end of the combustion, it is possible to change the ratio of comburent
to fuel by acting on combustion configurations (nr. 1,2,3).
Stove output setting
It allows you to set the fan speed
Displays the room temperature reading and is used to set the desired
temperature
Not used - keep in OFF to avoid erroneous pellet depletion warning
Enables or disables the timer. When enabled, the icon
steady (not flashing)
Submenus
and press
and then
"7"
Weekly timer
[1]
Programs
[2]
Time / date
[3]
Hours remaining
[4]
System information
[5]
Eco function
[7]
Restart delta
[8]
Frost protection
[9]
temperature
Lock keypad
[10]
Display brightness
[11]
Display mode
[12]
Buzzer volume
[13]
Combustion
Installer menu
[30]
Loading pellets
[31]
Service menu
[40]
DESCRIPTION
DESCRIPTION
Assigns the programs (max 3) to the different days of
the week
Program setting menu
Time and date setting
Displays the number of hours remaining until recommen-
ded maintenance. When "Hi" is displayed, the remaining
time exceeds 999 hours
Displays the current software version
Enables or disables Eco Mode, in which the stove
automatically switches off and on based on room
temperature
Difference in degrees from room temperature below
which the stove switches on again
Minimum temperature below which the stove switches
on
Disables the buttons on the keypad
Sets display brightness
Sets how the data is displayed
Sets the buzzer volume
Three different types of combustion can be set
Sets/displays the stove configuration
Manual activation of the pellet loading system
Menu reserved for the service centre
ENGLISH
VALUES
OFF*, 1–5; Auto; Hi
12°C - 51°C
will be displayed
ON – OFF
0,5°C - 5,0°C
1-5
VALUES
[d1] - [d7]
[P1] - [P6]
OFF; Eco
OFF;
3°C - 20°C
OFF; Lo; Hi
OFF; 1 - 5
OFF; 1 - 3
OFF; 1 - 5
1 - 3*