12 ALARM

If a malfunction occurs, the following procedure is
activated:
1) audible alarm (beep);
2) one of the following system LEDs come on:
;
3) if the problem concerns an error, the stove will switch
off.
Pressing and holding the "cancel" button
error code on the display:
ERROR/
WARNING
CODE
Faulty control panel
E001
Remote control signal
E002
communication error
Communication error
E004
Failed ignition error
E101
Pellet probe malfunction
E106
Pressure error or thermal safety
E108
Temperature probe malfunction
E110
Flue gas temperature probe
E111
malfunction
Scheduled maintenance warning
A002
(icons flashing)
Battery discharged
A004
Failure of the Hall sensor
A005
----
Clean stove
----
Failed ignition error
* In case of a blackout, it will be necessary to reset the stove when the power is restored (see section in this manual).
After having checked the type of message, the alarm
can be reset by pressing the on/off button
moments.
If the error code is "
E108
manually reset the thermostat located on the rear of
the stove (If the problem persists contact the technical
assistance centre).
shows the
DESCRIPTION
for a few
", before resetting the alarm,
POSSIBLE CAUSES
Control panel fault
Control panel fault
Connection cable between board and control panel
interrupted or detached.
If this appears when changing configuration, ignore
the error.
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Pellet probe disconnected or faulty
Flue gas exhaust system dirty
Seal gaskets worn
Insufficient combustion air
Problems with overheating in the pellet hopper
Faulty air temperature probe
Faulty flue gas temperature probe
The stove periodically requires maintenance to be
performed by a qualified technician
Battery discharged (mod. CR2032) *
Hall sensor of smoke fan disconnected or faulty
Combustion chamber, burn pot or flue gas exhaust
system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets
Faulty ignition heater
Worn gaskets
Incorrect burn pot position
Before proceeding with a new ignition, check that:
• the stove has cooled
• the burning pot is clean and free of any ash residue or
pellet
• the burning pot is correctly positioned in its seat
• the doors of the hearth and the tank are perfectly
closed