  • Page 1 Jøtul F 500 Oslo Noncatalytic Wood Stove USA/CAN - Installation and Operating Instructions Save these instructions for future reference.
  • Page 2: Standards And Codes

    OPERATING INSTRUCTIONS IN THIS MANUAL. This manual describes the installation and operation of the Jøtul F 500 Oslo non-catalytic wood heater. Read this entire manual before you install and use your new stove. Save these instructions This heater meets the 2015 U.S.
  • Page 3: Table Of Contents

    139681_R00 F 500 CB Oslo May, 2015 Table of Contents Safety Notices • BURN SOLID, NATURAL WOOD FUEL ONLY. DO NOT Standards and Codes .................2 BURN ANY OTHER FUEL. Safety Notices .....................3 • DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE. 1.0 Installation DO NOT BURN GARBAGE OR FLAMABLE FUELS.
  • Page 4: Installation

    139681_R00 F 500 CB Oslo May, 2015 1.0 Installation 2.1 Chimney Requirements T h e re a re t wo t y p e s o f c h i m n eys s u i t a b l e fo r t h e 1.1 Assembly before Installation Jøtul F 500: 1.
  • Page 5: Prefabricated Chimneys

    139681_R00 F 500 CB Oslo May, 2015 2.5 Wall Pass-throughs • The masonry chimney must have a fireclay liner or equivalent, with a minimum thickness of 5/8” (16mm) and must be When your installation unavoidably requires the chimney installed with refractory mortar. There must be at least 1/4” connector to pass through a combustible wall to reach the (6,35mm) air space between the flue liner and chimney wall.
  • Page 6: Connecting To The Chimney

    139681_R00 F 500 CB Oslo May, 2015 3.3 Prefabricated Chimneys See section 5.3.1 and 5.3.2 of CAN/CSA - B365-M91. Consult your local building inspector, authorized Jøtul Dealer, When installing the Jøtul F 500 to a prefabricated metal chimney NFPA 211 in the U.S. or CAN/CSA-B635 in Canada for other always follow the pipe manufacture’s instructions and be sure approved wall pass-through methods.
  • Page 7: Floor Protection

    139681_R00 F 500 CB Oslo May, 2015 4. The bottom heatshield is required in all alcove installations. If you are not sure of the combustible nature of a material, consult 5. H e a r t h p r o t e c t i o n m a t e r i a l m u s t c o n s i s t o f : your local fire officials.
  • Page 8: Operation

    DO NOT BURN: • Coal; Please read the following section completely before building a • Garbage; fire in your new Jøtul F 500 Oslo. • Synthetic fuel or logs; • Material containg rubber, including tires; 5.1 Combustion Efficiency • Material containing plastics;...
  • Page 9: Break-In Procedure

    139681_R00 F 500 CB Oslo May, 2015 5.6 Starting and Maintaining a Fire Use a Stove-top Thermometer Determining the primary air setting for the best overall Burn only solid wood directly on the bottom grate of the stove. performance for your particular needs and installation will be Do not elevate the fire in any way.
  • Page 10: Creosote Formation And Removal

    139681_R00 F 500 CB Oslo May, 2015 Creosote and Soot Formation and the Need for Removal When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. These creosote vapors condense in the relatively cool chimney flue of a slow burning fire.
  • Page 11: Maintenance

    139681_R00 F 500 CB Oslo May, 2015 6.0 Maintenance 6.3 Chimney System The Jøtul F 500 CB is designed to burn cleanly and efficiently Regular maintenance will prolong the life of your stove and when used according to the guidelines in this manual. In order ensure satisfactory performance.
  • Page 12: Gaskets

    Close and latch the door and then reopen. Wipe any combustion will not necessarily eliminate performance issues excess cement squeezed out from around the gasket. associated with negative pressure within the home or chimney system. F 500 Oslo Gaskets Floor Bracket Kit - 750304 Description Size Length Top Cover 3/8 in.
  • Page 13: Figures

    139681_R00 F 500 CB Oslo May, 2015 Fig. 1 a Fig.1 Fig. 1 b Fig. 3 Fig. 4 Fig. 1 c...
  • Page 14 139681_R00 F 500 CB Oslo May, 2015 Fig. 8 Fig. 5 2" (50 mm) 8" (200 mm) Min. width 50,5" 18" 8" ( 1283mm) (460 mm) (200 mm) 18" (460 mm) Min. width 56" (1422 mm) Fig. 6 Fig. 9 18"...
  • Page 15 139681_R00 F 500 CB Oslo May, 2015 Fig.11 Fig. 14 Fig.12 Fig.13...
  • Page 16: Clearance Chart And Diagrams

    139681_R00 F 500 CB Oslo May, 2015 Jøtul F 500 Woodstove Clearances Minimum clearance from Left Side Load Door to combustible surfaces is 36”. The side door must be locked in alcove and corner installations. Use Side Door Lock Kit 155850. Unprotected Surface Protected Surface PER NFPA 211 or...
  • Page 17: Vertical Installation

    139681_R00 F 500 CB Oslo May, 2015 Jøtul F 500 Woodstove Clearances Stove clearances Unprotected surface Protected surface NFPA 211 Parallel installation Parallel installation Side Rear Corner* Side Rear Corner* Stove- no heatshields 14” A 18” B 13” C 6” D 12”...
  • Page 18: Parts Schematic And Listing

    139681_R00 F 500 CB Oslo May, 2015...
  • Page 19: Appendix A (Alternate Floor Protection)

    139681_R00 F 500 CB Oslo May, 2015 Appendix A Pos. No. Description Pos. No. Description Latch Bolt Side Door Latch (Side Door) Sleeve Alternate Floor Protection Ash House Complete Wooden Knob + Small Parts Ash Door Hinge Pin Front/Side Door All floor protection materials must be non-combustible ie.
  • Page 20: Warranty Statement

    139681_R00 F 500 CB Oslo May, 2015 9.0 Jøtul North America Wood-burning Product Limited Lifetime Warranty Exclusions and Limitations Effective January 1, 2013 Notice: This warranty is void if installation or service is performed This warranty policy applies to wood-burning products identified by someone other than an authorized installer or service agency, by Jøtul and Scan trade names, as set forth below.
  • Page 21 139681_R00 F 500 CB Oslo May, 2015 Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the length of implied warranties. Therefore, the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state.
  • Page 22 139681_R00 F 500 CB Oslo May, 2015 This page is intentionally blank.
  • Page 23 139681_R00 F 500 CB Oslo May, 2015 This page is intentionally blank.
  • Page 24 139681_R00 F 500 CB Oslo May, 2015 Jøtul pursues a policy of continuous product development. Products supplied may therefore differ in specification, colour and type of accessories from those illustrated and described in the brochure. Jøtul North America Inc. 55 Hutcherson Drive Gorham, Maine 04038 Jøtul AS P.o.