Model And Suffix Codes - YOKOGAWA vigilantplant OX102 User Manual

Current limit type oxygen analyzer
Table of Contents

Advertisement

1.2 Model and Suffix Codes

Part Number
K9424GA
K9424JA
K9424JB
K9424JR
K9424JS
1-4
(1) OX102 Current limiting Type Oxygen Analyzer
Model
Suffix Code
• • • • • • • • • • • • • • • • • •
OX102
Measuring
-1
Range
1
2
Sensor
3
N
Manual
E
Optional Nipple *(1)
*(1) Either plastic or metal nipple should be specified according to the measuring range of the application,
if required. When the OX102 is used with a sampling unit, nipple is not required.
(2) Sample unit, calibration kit (optional)
Sampling unit
Calibration kit: 1000 ppm, 6 cylinders (1L) + needle valve assembly, with flow adjustment
Calibration kit: 1000 ppm, 6 cylinders (1L) + needle valve assembly, without flow adjustment
Calibration kit: 10000 ppm, 6 cylinders (1L) + needle valve assembly, with flow adjustment
Calibration kit: 10000 ppm, 6 cylinders (1L) + needle valve assembly, without flow adjustment
(3) Optional Accessories
Part Number
K9424GY
Activated carbon element (5 pieces/pack), for sampling unit
K9424JP
1000 ppm O
K9424JQ
10000 ppm O
K9424JC
Needle valve assembly, with flow adjustment
K9424JD
Needle valve assembly, without flow adjustment
K9424LA
Sensor assembly, specially designed for OX102
K9424LB
Extension cable, 4 m, specially designed for OX102
Extension cable, 9 m, specially designed for OX102
K9424LC
Extension cable, 29 m, specially designed for OX102
K9424LD
Metal nipple (ferrule; metal), Rc1/4, 100 to 150 C *
K9424DB
Metal nipple (ferrule; teflon), Rc1/4, For 100 C or less
K9424DF
Plastic nipple, 17 mm O.D. or G3/8 hole, for measuring range 0-1000 ppm or greater
L9811LA
Disk filter for Sampling Unit
K9424GQ
Felt filter for Sampling Unit
K9346WH
* The insertion length cannot be changed once a metal ferrule is tightened with a nipple. It is because
the ferrule engages with the sheath of the sensor once tightened.
Option Code
Current limit type oxygen analyzer
0-100/1000/10000 ppm/0-25%O
• • • • • • • • • •
5 m (1 m sensor assembly + 4 m cable)
• • • • • • • • • •
10 m (1 m sensor assembly + 9 m cable)
• • • • • • • • • •
30 m (1 m sensor assembly + 29 m cable)
• • • • • • • • • •
Not required
• • • • • • • • • •
Japanese
J
• • • • • • • • • •
English
• • • • • • • • • •
Plastic nipple, 17 mm O.D. or G3/8 hole, (for measuring
/J
range 0-1000 ppm or greater)
Metal nipple (ferrule; teflon), Rc1/4, (for measuring
/S
range 0-100 ppm)
Description
Description
calibration gas, 1L x 6 cylinders/box
2
calibration gas, 1L x 6 cylinders/box
2
Description
2
T1201E.EPS
T1202E.EPS
T1203E.EPS
IM 11M10A01-03E

Advertisement

Table of Contents
loading