Ezm Group & Area Options (Addr 0737-0749) - NAPCO Gemini GEM-P1632 Programming Instructions Manual

Global panel communicator
Table of Contents

Advertisement

Page 30
EZM Group 1
ADDRESS 0737
ADDRESS 0738
LEFT
RIGHT
LEFT
blank (•)
blank (•)
Default depends on Easy Menu Question "
not enabled, then all 6 groups will be automatically enabled. If 32 zones are used and Zone Doubling is enabled, then only groups 1-4 will be automatically enabled.
NOTE: If "Zone Doubling" (Address 0721) is not enabled, then Zones 1-8 are included in the control panel and Zones 9-32 (Groups
1-6) are EZM Zones. If "Zone Doubling" is enabled, then Zones 1-16 are included in the control panel and Zones 17-32 (Groups 1-4)
are EZM Zones and groups 5 and 6 must not be used.
EZM
EZM TYPE
TYPE
DATA
1
ENTRIES
OPTION
2
RIGHT
3
Not used
4
blank (•)
(No EZM
5
present)
6
1
4-Zone EZM
ADDRESS 0743
Priority Arming/
LEFT
RIGHT
Area 1
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 1
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•) blank (•)
Not Used
blank (•)
2
Enabled
Disarming Area 2
Area 1 Burg Output Silenced
Area 2 Burg Output Silenced
RESERVED
RESERVED
Disarming Area 2
Area 1 Pulsed Burg Output Silenced
Area 2 Pulsed Burg Output Silenced
RESERVED
RESERVED
OUTPUT TURNS OFF UPON DISARM: Select options for any of the 4 Outputs.
1. Select the desired option by circling
2. Add the data values (ex: 15=1+2+4+8) from the selected options.
3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available.
GEM-P1632 Programming Instructions
EZM Group 2
EZM Group 3
ADDRESS 0739
RIGHT
LEFT
blank (•)
       
ZONES COVERED
EZM GROUP OPTIONS: Up to 6 Groups of 4 Zones each may be
NORMAL DOUBLED
programmed depending on the number of zones used and which EZM
9-12
17-20
modules are connected. Each group represents 4 zones.
13-16
21-24
17-20
25-28
1. Select EZM type from the table shown.
21-24
29-32
2. Enter in corresponding address locations above (right digit only).
25-28
29-32
NOTE: Dark shaded data value box shows option not available.
ADDRESS 0744
Priority Arming/
LEFT
Area 2
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 2
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•) blank (•)
Not Used
blank (•)
1
Enabled
Burglary Output Turns Off
LEFT DATA
VALUES
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) blank (•)]
Pulsed Burg Output Turns Off
LEFT DATA
VALUES
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) blank (•)]
the data values for right digit only (left is not used).
EZM Group 4
ADDRESS 0740
RIGHT
LEFT
RIGHT
blank (•)
    
" and "
PRIORITY AREA ARMING:
RIGHT
1. Select option from the table shown.
2. Enter in corresponding right digit address location (left digit
is not used).
NOTE: Dark shaded data value box shows option not available.
upon Disarm
ADDRESS 0745
RIGHT DIGIT (SUM
OF DATA VALUES)
upon Disarm
ADDRESS 0746
RIGHT DIGIT (SUM
OF DATA VALUES)
EZM Group 5
ADDRESS 0741
LEFT
RIGHT
blank (•)
". For example, If 32 zones are used and Zone Doubling is
RIGHT DATA
VALUES
Disarming Area 1
)
(CIRCLE
Area 1 Burg Output Silenced
1
Area 2 Burg Output Silenced
2
RESERVED
4
RESERVED
8
RIGHT DATA
Disarming Area 1
VALUES
)
(CIRCLE
Area 1 Pulsed Burg Output Silenced
1
Area 2 Pulsed Burg Output Silenced
2
RESERVED
4
RESERVED
8
NAPCO Security Systems
WI897B 8/98
EZM Group 6
ADDRESS 0742
LEFT
RIGHT
blank (•)