This section will focus on configuring the GEM-RP1CAe2 and GEM-RP2ASe2 Keypads. If there is more than one keypad in the sys-
tem, only Keypad No. 1 may be used for programming.
Two types of keypads may be used with the GEM-P1632: the GEM-RP1CAe2 and the GEM-RP2ASe2. Each must be assigned an
address number (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and
DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial
Burglary installation.
GEM-RP1CAe2 - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a PGM output. A
GEM-RP1CAe2 is recommended for use as Keypad #1.
GEM-RP2ASe2 - is a utility LCD keypad combining several preset LCD words with a limited message line. NOTE: Due to space con-
straints, available messages are abbreviated and will scroll automatically.
A total of up to 7 keypads may be connected to the panel. GEM-RP1CAe2 and GEM-RP2ASe2 keypads may be intermixed but re-
quire different configuration procedures, as described in the following paragraphs.
Configuring the GEM-RP1CAe2 Keypad
Each GEM-RP1CAe2 keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d) compatibility
number; (e) EZM address; and (f) zone response.
 
To enter the GEM-RP1CAe2 Configuration Mode:
1. Move jumper JP1 (located at the upper-right corner of the control panel board) from Pins 1-2 (top two) to Pins
2-3 (bottom two). NOTE: See Wiring Diagram on page 72.
2. After about 15 seconds, the display will read "     ", where XX indicates the keypad address.
3. Press
for all keypads.)
Entry Sounder
Keypad Address

1. Enter the assigned keypad number 01–07, then press the
beep; an invalid number will be rejected by a long beep.
2. Press the
button to continue or press the
GEM-P1632 Programming Instructions
and proceed as follows. (Repeat the following procedure
Keypad Tactile Beep
Upon entering the Keypad Configuration Mode, "     " will be displayed,

indicating that the tactile beep, which sounds when any button is pressed, is on. To
turn off the tactile beep, press the
beep on and off).
Press the
button to continue or press the

To turn off the keypad sounder during entry time, press the
ton will toggle the tactile beep on and off). Press the
press the
button to exit.
If more than one keypad is installed, each must be assigned a unique keypad ad-
dress (that is, no two keypads may be numbered alike):
keypads must be numbered consecutively (missing numbers are not permitted)
only Keypad No. 1 may be used for programming.
To assign the keypad number, proceed as follows:

button to save. A valid number will be acknowledged by a short
button to exit.
NORMAL
KEYPAD
CONFIGURE

button (the
button will toggle the tactile
button to exit.

button (the
button to continue or
NAPCO Security Systems
WI897B 8/98

    
 
      
 
    
 

 


NEXT/YES

 

PRIO R/NO
 

ARE A
     
R
but-

Hide quick links: