EZM Group 1
EZM Group 2
ADDRESS 1455
ADDRESS 1456
LEFT
RIGHT
LEFT
blank
blank
Default depends on Easy Menu Question "# OF ZNS IN AREA 1 ENTER # ZONES" and "EZ ZONE DOUBLING? Y/N". For example, if
32 Zones are used and Zone Doubling is not enabled, then all 6 Groups will be automatically enabled. If 32 Zones are
used and Zone Doubling is enabled, then only Groups 1-4 will be automatically enabled.
NOTE: If "Zone Doubling" (Address 1423, option 1) is not enabled, then Zones 1-8 are included in the control panel
and Zones 9-32 (Groups 1-6) are EZM Zones. If "Zone Doubling" is enabled, then Zones 1-16 are included in the
control panel and Zones 17-32 (Groups 1-4) are EZM Zones (and Groups 5 and 6 must not be used).
EZM TYPE
EZM
DATA
GROUP
ENTRIES
OPTION
Not used
blank (•)
(No EZM
present)
1
4-Zone EZM
Priority
Arming
Area 1
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 1
DATA ENTRIES
LEFT
blank (•)
blank (•)
PRIORITY AREA ARMING:
1. Select option from the table shown.
2. Enter in corresponding right digit address location (left digit is not used).
NOTE: Dark shaded data value box shows option not available.
U
3. Press
to save.
X
GEM-P1632 Programming Instructions
EZM GR OUP OPTIONS (ADDRE S S 1455-1460)
EZM Group 3
ADDRESS 1457
RIGHT
LEFT
blank
ZONES COVERED
NORMAL
DOUBLED
1
9-12
17-20
2
13-16
21-24
3
17-20
25-28
4
21-24
29-32
5
25-28
6
29-32
AREA ARMING OPTI ONS (ADDRE SS 1469-1 470)
ADDRESS 1469
LEFT
RIGHT
blank (•)
OPTION
RIGHT
blank (•)
Not Used
1
Enabled
EZM Group 4
ADDRESS 1458
RIGHT
LEFT
RIGHT
blank
EZM GROUP OPTIONS: Up to 6 Groups of 4 Zones each may be pro-
grammed depending on the number of Zones used and which EZM mod-
ules are connected. Each Group represents 4 Zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations
above.
NOTE: Dark shaded data value box shows option not available.
U
3. Press
to save.
Priority
ADDRESS 1470
Arming
LEFT
RIGHT
Area 2
blank (•)
[Default = blank (•) blank (•)]
PRIORITY ARMING/AREA 2
DATA ENTRIES
OPTION
LEFT
RIGHT
blank (•)
blank (•)
Not Used
blank (•)
1
Enabled
WI1148B 10/06
EZM Group 5
EZM Group 6
ADDRESS 1459
ADDRESS 1460
LEFT
RIGHT
LEFT
blank
blank