External Relay Control (Addr 0750-0829) - NAPCO Gemini GEM-P1632 Programming Instructions Manual

Global panel communicator
Table of Contents

Advertisement

WI897B 8/98
ADDRESS 0750-0754 (RELAY EVENT 1)
0750
0751
0752
0753
L
R
L
R
L
R
L
R
(•)
(•)
ADDRESS 0765-0769 (RELAY EVENT 4)
0765
0766
0767
0768
L
R
L
R
L
R
L
R
(•)
(•)
ADDRESS 0780-0784 (RELAY EVENT 7)
0780
0781
0782
0783
L
R
L
R
L
R
L
R
(•)
(•)
ADDRESS 0795-0799 (RELAY EVENT 10)
0795
0796
0797
0798
L
R
L
R
L
R
L
R
(•)
(•)
ADDRESS 0810-0814 (RELAY EVENT 13)
0810
0811
0812
0813
L
R
L
R
L
R
L
R
(•)
(•)
ADDRESS 0825-0829 (RELAY EVENT 16)
0825
0826
0827
0828
L
R
L
R
L
R
L
R
(•)
(•)
RELAY EVENT OPTIONS
RELAY # AREA
Timeout Event ID COND.
L
R
L
R
L
R
L
R
(•)
(•)
1
2
3
4
TIMEOUTS: Each relay event can be assigned a timeout depending on Alarm Type option.
3. If Alarm Type (see next page) is selected for timeout in minutes or seconds, select the timeout from the table shown in minutes
or seconds and enter in corresponding address location (left digit and right digits).
TIMEOUTS
(Alarm Type is selected for
Timeout Type in min. or sec.)
DATA ENTRIES
TIMEOUT
LEFT
RIGHT
0 min./sec.
blank (•) blank (•)
blank (•)
1
1 min./sec.
blank (•)
2
2 min./sec.
blank (•)
3
3 min./sec.
blank (•)
4
4 min./sec.
blank (•)
5
5 min./sec.
blank (•)
6
6 min./sec.
blank (•)
7
7 min./sec.
blank (•)
8
8 min./sec.
blank (•)
9
9 min./sec.
blank (•)
0
10 min./sec.
NAPCO Security Systems
ADDRESS 0755-0759 (RELAY EVENT 2)
0754
0755
0756
L
R
L
R
L
R
(•)
(•)
ADDRESS 0770-0774 (RELAY EVENT 5)
0769
0770
0771
L
R
L
R
L
R
(•)
(•)
ADDRESS 0785-0789 (RELAY EVENT 8)
0784
0785
0786
L
R
L
R
L
R
(•)
(•)
ADDRESS 0800-0804 (RELAY EVENT 11)
0799
0800
0801
L
R
L
R
L
R
(•)
(•)
ADDRESS 0815-0819 (RELAY EVENT 14)
0814
0815
0816
L
R
L
R
L
R
(•)
(•)
[Default = blank (•) blank (•) from address 0750-0829]
RELAY # OPTIONS: Each relay event can be assigned to any of the 8
0829
available external relays from Relay Module RM3008. Multiple relay
L
R
events can drive the same External Relay.
1. Select the relay from the table shown; enter in corresponding
right digit address location (left digit is not used).
L
R
AREA OPTIONS: Each relay event can be assigned to Area 1, Area 2
or both Area 1 & Area 2.
2. Select the area from the table shown;
enter in corresponding right digit address
5
location (left digit is not used).
TIMEOUTS
(Alarm Type is selected for
Timeout Type in min. or sec.)
DATA ENTRIES
TIMEOUT
LEFT
RIGHT
11 min./sec.
blank (•)
B
blank (•)
C
12 min./sec.
blank (•)
D
13 min./sec.
blank (•)
E
14 min./sec.
blank (•)
F
15 min./sec.
1
blank (•)
16 min./sec.
1
1
17 min./sec.
1
2
18 min./sec.
1
3
19 min./sec.
1
4
20 min./sec.
1
5
21 min./sec.
0757
0758
0759
L
R
L
R
L
R
0772
0773
0774
L
R
L
R
L
R
0787
0788
0789
L
R
L
R
L
R
0802
0803
0804
L
R
L
R
L
R
0817
0818
0819
L
R
L
R
L
R
ENTRY
blank (•)
TIMEOUTS
(Alarm Type is selected for
Timeout Type in min. or sec.)
DATA ENTRIES
TIMEOUT
LEFT
RIGHT
11 min./sec.
1
6
1
7
12 min./sec.
1
8
13 min./sec.
1
9
14 min./sec.
1
0
15 min./sec.
1
B
16 min./sec.
1
C
17 min./sec.
1
D
18 min./sec.
F
F
2550 min./sec.
GEM-P1632 Programming Instructions
ADDRESS 0760-0764 (RELAY EVENT 3)
0760
0761
0762
0763
L
R
L
R
L
R
L
(•)
(•)
ADDRESS 0775-0779 (RELAY EVENT 6)
0775
0776
0777
0778
L
R
L
R
L
R
L
(•)
(•)
ADDRESS 0790-0794 (RELAY EVENT 9)
0790
0791
0792
0793
L
R
L
R
L
R
L
(•)
(•)
ADDRESS 0805-0809 (RELAY EVENT 12)
0805
0806
0807
0808
L
R
L
R
L
R
L
(•)
(•)
ADDRESS 0820-0824 (RELAY EVENT 15)
0820
0821
0822
0823
L
R
L
R
L
R
L
(•)
(•)
DATA
ENTRY
RIGHT
blank (•)
1
2
3
4
5
DATA
6
OFF/ON AREA
7
DISARM
RIGHT
8
NONE
1
Area 1
2
Area 2
3
Area 1 & Area 2
For a desired delay/timeout not listed
do the following:
A. Choose a desired delay/timeout,
ex: 20 min.
B. Divide it by 16
1 Quotient
Left Digit
16 20
16
4 Remainder
Right Digit
EVENT ID CODES & CONDITIONS
ARE ON NEXT PAGE
Page 35
0764
R
L
R
0779
R
L
R
0794
R
L
R
0809
R
L
R
0824
R
L
R
RELAY #
NONE
1
2
3
4
5
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents