ADDRESS 1180
Number of RF
LEFT
RIGHT
Receivers
blank (•)
Default for Number of Receivers de-
pends on Easy Menu Question for RF
Transmitters.
RF SUPERVISORY
RF TRANSMITTER
TIMER
Type 0
Window/Door, 2 Pt.
Type 1
Window/Door, 2 Pt.
Type 2
Window/Door, 2 Pt.
Type 3
Window/Door, 2 Pt.
Type 4
Window/Door, 4 Pt.
Type 5
PIR
Type 6
PIR
Type 7
Smoke Detector
[Default = blank (•) blank (•) from address 1038-1045]
RF SUPERVISORY TIMERS
DATA ENTRIES
DELAY
LEFT
RIGHT
blank (•) blank (•)
0 min.
blank (•)
1
30 min.
blank (•)
2
60 min.
blank (•)
3
90 min.
blank (•)
4
120 min.
blank (•)
5
150 min.
blank (•)
6
180 min.
blank (•)
7
210 min.
blank (•)
8
240 min.
blank (•)
9
270 min.
blank (•)
0
300 min.
blank (•)
B
330 min.
blank (•)
C
360 min.
blank (•)
D
390 min.
blank (•)
E
420 min.
blank (•)
F
450 min.
1
blank (•)
480 min.
1
1
510 min.
1
2
540 min.
1
3
570 min.
1
4
600 min.
1
5
630 min.
1
6
660 min.
1
7
690 min.
1
8
720 min.
1
9
750 min.
1
0
780 min.
1
B
810 min.
1
C
840 min.
1
D
870 min.
1
E
900 min.
1
F
930 min.
2
blank (•)
960 min.
2
1
990 min.
2
2
1020 min.
2
3
1050 min.
2
4
1080 min.
2
5
1110 min.
GEM-P1632 Programming Instructions
DATA
ENTRIES
RF Receiver(s)
RIGHT
blank (•)
None
1
1
2
2
ADDRESS
1038-1045
LEFT
ADDR
RIGHT
1038
1039
1040
1041
1042
1043
1044
1045
RF SUPERVISORY TIMERS
DATA ENTRIES
DELAY
LEFT
RIGHT
2
6
1140 min.
2
7
1170 min.
2
8
1200 min.
2
9
1230 min.
2
0
1260 min.
2
B
1290 min.
2
C
1320 min.
2
D
1350 min.
2
E
1380 min.
2
F
1410 min.
3
blank (•)
1440 min.
3
1
1470 min.
3
2
1500 min.
3
3
1530 min.
3
4
1560 min.
3
5
1590 min.
3
6
1620 min.
3
7
1650 min.
3
8
1680 min.
3
9
1710 min.
3
0
1740 min.
3
B
1770 min.
3
C
1800 min.
3
D
1830 min.
3
E
1860 min.
3
F
1890 min.
4
blank (•)
1920 min.
4
1
1950 min.
4
2
1980 min.
4
3
2010 min.
4
4
2040 min.
4
5
2070 min.
4
6
2100 min.
7650 min. = 127
F
F
Hr., 30 min.
RF RECEIVERS: Up to 2 RF Receivers may be programmed.
NOTE: This adds wireless capability to the system, increasing
up to 32 the number of zones. Also, the corresponding EZM
Group Number must be enabled (see address 0737-0742).
1. Select the number of receivers from the table shown.
2. Enter in corresponding right digit address location shown
(left digit is not used).
RF SUPERVISORY
TIMER
Type 8
Type 9
Type A
Type B
Type C
Type D
Type E
Type F
[Default = blank (•) blank (•) from address 1046-1053]
RF SUPERVISORY TIMERS: RF Supervisory Timers may be pro-
grammed for each type of transmitter used. A transmitter will send a
transmission every time it is tripped, when there is NO activity, the
transmitter sends a status transmission about once an hour. If the
receiver does NOT receive ANY signal (a trip or a status) from a
transmitter in the time specified for transmitter type, a system trouble "
   
" will be displayed at the keypad.
1. Select timer delay from the table shown. Timers are programmed
in increments of 30 minutes each. Valid entries are 03-FF, 90
minutes-7650min (127hr,30min).
WARNING: Timers have uncertainty of +0/-30 minutes. Do not
use entries 0-2 (shaded areas).
2. Enter in corresponding address locations above (left and right
digits).
3. For a desired timer not listed do the following:
A. Choose a desired timer (intervals of 30),
ex: 3000 min. (50 Hours)
B. Divide it by 30, ex: 3000/30 = 100
C. Divide it by 16
6 Quotient
16 100
96
4 Remainder
NOTE: These timers apply only to Supervised RF Transmitters (see
RF Transmitters in Easy Menu Driven Mode Programming).
WI897B 8/98
ADDRESS
RF TRANSMITTER
1046-1053
LEFT
ADDR
Smoke Detector
1046
Keyfob
1047
Dual Tech.
1048
Keyfob
1049
Window/Door, 4 Pt.
1050
PIR
1051
Smoke Detector
1052
Napco Glass Break
1053
Left Digit
Right Digit