Step 4: Connect The Grounding Cable - Juniper MX2010 3D Quick Start Manual

Universal edge router
Table of Contents

Advertisement

MX2010 3D Universal Edge Router Quick Start

Step 4: Connect the Grounding Cable

44
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to an approved site ESD grounding point. See the instructions for your site.
Connect the grounding cable to a proper earth ground.
2.
Verify that a licensed electrician has attached the cable lug provided with the router
3.
to the grounding cable.
Make sure that grounding surfaces are clean and brought to a bright finish before you
4.
make grounding connections.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
5.
the strap to one of the ESD points on the chassis. For more information about ESD,
see the
MX2010 3D Universal Edge Router Hardware Guide
Place the grounding cable lug over the grounding points. The upper pair is sized for
6.
UNC 1/4-20 bolts, and the lower pair is sized for M6 bolts.
Secure the grounding cable lug to the grounding points, first with the washers, then
7.
with the nuts (see
Figure 33 on page
Figure 33: Grounding Points on the MX2010 Router
Verify that the grounding cabling is correct, that the grounding cable does not touch
8.
or block access to router components, and that it does not drape where people could
trip on it.
.
44).
Copyright © 2014, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents