Appendix D - Adm Event And Error Codes Overview; Event Codes - Graco VRM 24F872 Instructions Manual

Hydraulic, plural-component, variable-ratio proportioner
Table of Contents

Advertisement

Appendix D - ADM Event and Error Codes Overview

Event Codes

Event Code and
String
Triggers
EAA0-R: Base Purge Base purge performed
EAD0-R: Pump(s)
One or both pumps were parked
Parked
EA10-R: Red Pump
The red pump has been primed
Prime
EA20-R: Blue Pump
The blue pump has been primed
Prime
EA00-R: Disp.
A dispense has occurred of the given
Occurred (Shot #)
shot number.
EAR0-R: Night Mode
While in night mode the system has
Recirc On
automatically entered a low recircula-
tion mode and attempted to turn on all
enabled conditioning zones.
EB00-R: Stop Button
The Red stop button was pressed on
Pressed
the Advanced Display Module.
EBR0-R: Night Mode
While in night mode the system has
Recirc Off
automatically stopped the low recircu-
lation mode and turned off all condi-
tioning zones.
EBR1-R: Setup val-
One or more of the setup values has
ues changed
changed.
ECA1-R: Red Mate-
The Red materials specific gravity was
rial SG Modified
modified.
ECB2-R: Blue Mate-
The Blue materials specific gravity was
rial SG Modified
modified.
ECH0-R: Learn Mode
A learn mode calibration was success-
Executed
fully completed.
EC1X-R: Ratio Mon.
User has changed one of the Ratio
Setup Changed
Monitoring parameters on the Setup
System #3 screen.
EH00-R: Gel Timer
The gel timer expired and the system
Dispense
automatically took the gel shot.
EL00-R: System
The System was powered on.
Powered On
EM00-R: System
The System was powered off.
Powered Off
ENC1-R: Cal. Point 1
A value for the first point in the three
Weight Entered
point calibration was entered.
ENC2-R: Cal. Point 2
A value for the second point in the
Weight Entered
three point calibration was entered.
ENC4-R: Cal. Point 1
The running average for point one of
Weight Erased
the three point calibration was erased.
ENC5-R: Cal. Point 2
The running average for point two of
Weight Erased
the three point calibration was erased.
END0-R: Ratio Check
A ratio check shot was dispensed from
Dispense
the ratio check calibration screen.
313873J
Appendix D - ADM Event and Error Codes Overview
Event Code and
String
Triggers
ENN0-R: Automatic
The system was successfully charac-
Cal. Performed
terized with the Automatic calibration.
EQU1-R: Settings
The system settings were successfully
Downloaded
transferred from the ADM to a USB
drive.
EQU2-R: Settings
The system settings file was success-
Uploaded
fully transferred from the USB drive to
the ADM.
EQU3-R: Language
The custom language file was suc-
Downloaded
cessfully transferred from the ADM to
a USB drive.
EQU4-R: Language
The custom language file was suc-
Uploaded
cessfully transferred from the USB
drive to the ADM.
EQU5-R: Logs Down-
The Error/Event and Shot data logs
loaded
were successfully transferred from the
ADM to a USB drive.
ER01-R: Shot Count
A counter from the shot counters main-
Reset
tenance page was erased
ER02-R: Seq. Posi-
A counter from the sequence counters
tion Count Reset
maintenance page was erased
ERA1-R: Red Mate-
The resettable totalizer for the Red
rial Volume Reset
material volume was reset to zero.
ERA2-R: Red Mate-
The resettable totalizer for the Red
rial Weight Reset
material weight was reset to zero.
ERA3-R: Red Cycle
The resettable cycle counter for the
Count Reset
Red pump was reset to zero.
ERB1-R: Blue Mate-
The resettable totalizer for the Blue
rial Volume Reset
material volume was reset to zero.
ERB2-R: Blue Mate-
The resettable totalizer for the Blue
rial Weight Reset
material weight was reset to zero.
ERB3-R: Blue Cycle
The resettable cycle counter for the
Count Reset
Blue pump was reset to zero.
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrm 24f391Vrm 24f873

Table of Contents