6-18
ELECTRICAL SYSTEM
IGNITION SYSTEM
W/R
W/R
Br
Generator
TROUBLESHOOTING
No spark or poor spark
NOTE:
Check that the engine stop switch, parking brake switch is in the "RUN", "ON" and "SET" positions. Check
that the fuse is not blown and the battery is fully-charged before diagnosing.
Step 1
1) Check the ignition system couplers for poor connections.
Is there connection in the ignition system couplers?
YES
Go to Step 2.
NO
Poor connection of couplers.
Br
CDI unit
B/W
O
Ignition
switch
CKP
R
sensor
B
W/B
W/B
O/W
O
O/W
O/W
O/W
O
O
O
Fuse 10A
R
R
Parking
brake
switch
Engine
stop
switch
Ignition
coil
B/W
Battery
Spark
plug