6-16
ELECTRICAL SYSTEM
STARTER MOTOR INSTALLATION
• Tighten the starter motor lead wire mounting bolt 1 and
starter motor mounting bolts 2 .
• Tighten the starter motor lead wire mounting bolt to the speci-
fied torque.
Starter motor lead wire mounting bolt:
STARTER RELAY INSPECTION
• Remove the seat. (
• Disconnect the battery - lead wire from the battery.
• Remove the starter relay cover 1 .
• Disconnect the starter relay coupler 2 .
• Disconnect the battery + lead wire 3 starter motor lead wire
4 .
• Remove the starter relay 5 .
• Apply 12 V to A and B terminals and check for continuity
between the positive and negative terminals using the
multi-circuit tester. If the starter relay clicks and continuity is
found, the relay is ok.
09900-25008: Multi-circuit tester set
Tester knob indication: Continuity test (
Do not apply battery voltage to the starter relay for
more than five seconds, since the relay coil may over-
heat and get damaged.
4 N·m (0.4 kgf-m, 3.0 lb-ft)
5-4)
)