PJLink security authentication
The password used for PJLink is the same as that of the password set for web control.
When using the projector without security authentication, do not set a password for web control.
f For specifications related to PJLink, refer to the website of Japan Business Machine and Information System
Industries Association.
URL http://pjlink.jbmia.or.jp/english/
Using Art-Net function
Since projector supports the Art-Net function, the projector settings can be performed via the Art-Net protocol on
the DMX controller or using application software.
Channel definition
The following table lists the channel definitions used for controlling the projector with the Art-Net function.
Channel
Control details
1
Light volume adjustment
2
Input/mode selection
6
Lens focus
7
Lens zoom
8
Power supply control
11
Lock
Note
f If the projector is operated with the remote control or by the control command while controlling the projector using the Art-Net function, the
setting of the DMX controller and the computer application may be different from the projector status. In this case, set "Lock" of channel 11
to "Operation not available" and then set back to "Operation available" so that the controls of all channels are applied to the projector.
Control commands via LAN
When the projector is connected to a computer via a LAN, the computer can use control commands to operate the
projector and query its status.
Chapter 7 Appendix — Technical information
Performance
100 %
...
0 %
No operation
HDMI
Lighting
No operation
Focus adjustment (-) fast
Focus adjustment (-) moderate
Focus adjustment (-) slow
No operation
Focus adjustment (+) slow
Focus adjustment (+) moderate 192-223
Focus adjustment (+) fast
Zoom adjustment (-) fast
Zoom adjustment (-) moderate
Zoom adjustment (-) slow
No operation
Zoom adjustment (+) slow
Zoom adjust (+) moderate
Zoom adjustment (+) fast
Power standby
No operation
Power on
Operation not available
Operation available
Parameter
0
Can be set in 256 steps between
...
100 % and 0 %.
255
0-7
8-15
16-23
24-255
0-31
32-63
64-95
96-159
160-191
224-255
0-31
32-63
64-95
96-159
160-191
192-223
224-255
0-63
64-191
192-255
0-127
When "Operation not available"
is set, operations of all channels
128-255
become unacceptable.