7.3.8. MONOCHROME EVF SECTION
Note:
Camcorder need NOT to be powered off and on after each
adjustment procedure.
Preparation
1. Before adjusting the Monochrome EVF, Camera section and VCR
section adjustments must be completely adjusted.
2. Remove the EVF Case B Unit to gain access to VRs on the EVF
C.B.A. (Refer to
7.3.8.1. Vertical Size Adjustment
Purpose:
To set the standard vertical size on the EVF picture.
Symptom of Misadjustment:
The vertical EVF picture size will be abnormal.
Test Point: ----------
Adjustment: VR901 (EVF C.B.A.)
Specification: Best Vertical size
Input: Gray Scale Chart
Mode: SP REC
Equipment: Viewfinder
Adjustment Procedure:
1. Aim the camcorder at the gray scale chart.
2. Adjust the VERTICAL SIZE CONTROL (VR901) so that the vertical
picture size becomes correct.
7.3.8.2. Centering Adjustment
Purpose:
"DISASSEMBLY/ASSEMBLY
Fig. E5-2
PROCEDURES".)