3. Install the Lock Screw in the Hole (Threaded Hole for Lock Screw
access) in Position "B".
4. Hold down the Cassette Up Unit.
5. Confirm that Cassette Up Unit will be held in the down Position.
5.1.3.2. Lock Screw is required when:
1. performing "Tape Interchangeability Adjustment."
2. performing"PC-EVR Adjustment" with cassette tape.
3. servicing with cassette tapein Service Position. The procedure
below is required when the unit is in safety defeat mode.
A. Confirm that the Lock Lever, shown in gray, is set to Position
"A" as shown in Fig. 2-1, and that the mechanism is in the
STOP position.
B. Insert the cassette tape.
C. Push Portion (a) as shown in Fig. 2-1 while keeping the
Cassette Up Unit in the down position so the mechanism starts
loading. (Cassette Down Switch is ON.)
10