Power Supply - Keurig Eccellenza Momentum Service Manual

Hide thumbs Also See for Eccellenza Momentum:
Table of Contents

Advertisement

Power Supply

Disconnect the service cord from the wall outlet prior to attempting to
replace any of the components in this section. Failure to do so can result in
an electrical shock!
1.
Remove the rear panel of the machine (this is the easiest way to access the power
supply mounting screws).
2.
Remove the waste bin and the floor tray, and open the front door.
3.
Remove the brewer and the grounds chute.
4.
Remove the brewer motor and brewer wiper motor support (see
5.
Disconnect the wires from the terminal blocks (on both sides of the power supply) by
removing the plastic cap, and then removing the screws securing the individual wires.
Do not lose the small screws and square washers when removing the wiring
terminals from the power supply as these are not available as service parts.
6.
From the rear of the machine, loosen (but do not remove) the four power supply
mounting screws.
VKI Publication #202378-001
Eccellenza Momentum™
page
33).