Charger Error Codes
Error Code
E-0-2-1
High battery voltage detected while
charging
E-0-2-2
Low battery voltage detected while
charging
E-0-2-3
High AC voltage
E-0-2-4
Failure to initialize
E-0-2-5
Low AC voltage oscillation
E-0-2-6
Script failure
E-0-2-7
USB over current fault
E-0-2-8
Charge profile incompatibility
Part No. 1309020GT
Description
GS
-30m • 32m • 30 • 32 • 46 • 55
Condition
Battery voltage too high as
detected by charger profile.
Battery voltage too low as
detected by charger profile.
AC voltage greater than 270 VAC.
Charger failed to turn on correctly.
AC voltage unstable.
Software update failed.
USB over current protection has
been tripped.
Selected charger profile is not
compatible with charger software.
Service and Repair Manual
Battery Charger
Possible Causes
Check battery voltage and cable
connections.
Confirm charger profile is
programmed for correct battery
type.
Self clearing when condition has
been corrected.
Check battery voltage and cable
connections.
Confirm charger profile is
programmed for correct battery
type.
Self clearing when condition has
been corrected.
Connect to a stable AC source
between 85 - 270 VAC / 45 - 65
Hz.
Self clearing when condition has
been corrected.
Disconnect AC input and battery
pack for 30 seconds.
Contact Genie Product Support.
Connect to a stable AC source
between 85 - 270 VAC / 45 - 65
Hz.
Using an undersized generator.
Self clearing when condition has
been corrected.
Confirm USB Flash Drive is
formatted with correct software.
If software update continues to fail,
contact Genie Product support.
Remove and re-insert USB Flash
Drive.
Use different USB Flash drive.
Update charger software.
Confirm charger profile is
programmed for correctly.
Updating current firmware and
error occurs, contact Genie
Product Support.
205