Item
Description of
functions
FB compilation
method
FB behavior
i_bEN input condition
When Execution Command (i_bEN) is turned ON, this FB executes the settings on the controller
specified by Set Controller (i_uSetController) in accordance with the various input values.
If Execution Command (i_bEN) is turned ON with Read Flag (i_bReadFlag) ON, however, all the
hold settings for all the connected controllers are output to Read Hold Setting
(o_u15ReadHoldSetting) in accordance with the data values shown in the table below. In this case,
other set values are ignored, and no setting takes place. If Read Flag (i_bReadFlag) is OFF, you can
execute various settings by entering the data values corresponding to hold settings in Hold Setting
(i_uHoldSetting).
Setting
Measurement mode
values
0
Sample hold
1
Peak hold
2
Bottom hold
3
Peak-to-peak hold
4
Peak-to-peak hold/2
5
NG hold
6
Self sample hold
7
Self peak hold
8
Self bottom hold
For more information on the output operation in each measurement mode, refer to "Contact-Type
Digital Displacement Sensor HG-S Series User's Manual"
Macro type
Pulse execution type (multi-scan execution type)
None
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Description
Trigger mode
One shot
Hold
-
-
-
-
-
-
-
53/184
Self trigger
edge direction
Leading edge
Static span
Trailing edge
Delay timer
-
-
-
-
-
-
WUME-SCHG1IQRFB-1
Self trigger
delay
-
-
-
-
-
-

Advertisement