■ Output labels
Name
Execution Status
o_bENO
Normal Completion
o_bOK
Error Completion
o_bErr
Error Code
o_uErrId
Module Error Code
o_ud16ModuleErrId[n]
FB Version Upgrade History
Version
00A
Precaution
This chapter describes the functions of function blocks (FBs).
Restrictions on the use of modules and sequencer CPUs and on their combinations are not included in the scope of this chapter.
Before use, be sure to read the User's Manuals of the products you are going to use.
Variable name
Data type
Bit
Bit
Bit
Word
[Unsigned]
Double word
[Unsigned]
Date
2018/03/06
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Default
OFF
Stays ON while the FB is running.
OFF
Turns ON upon normal completion of the FB.
OFF
Turns ON upon error completion of the FB.
0
Stores the error code that occurred in the FB.
Stores the error code that occurred in the
communication unit.
16 arrays exist and store module error codes.
n=0: Master device
0
n=1: 1st slave device
to
n=14: 14th slave device
n=15: Communication unit