Panasonic SC-HG1 Series Reference Manual page 25

For mitsubishi melsec iq-r series sequencer
Table of Contents

Advertisement

Item
Description of
functions
FB compilation
method
FB behavior
i_bEN input condition
When Execution Command (i_bEN) is turned ON, this FB outputs the connected controller output
to Sensor Output (o_u3SensorOutput) as 16-bit word data and outputs the output data to Detected
Value (o_d15DetectedValue) in accordance with the input value of Response Data
(i_uResponseData).
Response Data (i_uResponseData) input value
* For information on the judgment value, normal measurement value, calculated value, and sensor
head value, refer to "Contact-Type Digital Displacement Sensor HG-S Series User's Manual".
Sensor Output (o_uSensorOutput) has three arrays and outputs the output data in accordance with
the following table.
Sensor output
Macro type
Pulse execution type (multi-scan execution type)
None
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Description
0
1
2
3
Output label
o_u3SensorOutput[0]
o_u3SensorOutput[1]
o_u3SensorOutput[2]
25/184
Output data
Judgment value*
Normal measurement value*
Calculated value*
Sensor head value*
Output data
Controller judgment output 1
Controller judgment output 2
Controller judgment output 3