■ Output labels
Name
Execution Status
Normal Completion
Error Completion
Error Code
Sensor output
Detected value
Variable name
o_bENO
o_bOK
o_bErr
o_uErrId
o_u3SensorOutput[n]
o_d15DetectedValue[n]
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Data type
Default
Bit
OFF
Bit
OFF
Bit
OFF
Word
0
[Unsigned]
Word
0
[Unsigned]
Double
word
0
[Signed]
30/184
Description
Stays ON while the FB is running.
Turns ON upon normal completion of the FB.
Turns ON upon error completion of the FB.
Stores the error code that occurred in the FB.
Stores the word information (consisting of 16
pieces of bit information) that represents the
connected controller's output status.
bit 0: Master device
bit 1: 1st slave device
to
bit 13: 13th slave device
bit 14: 14th slave device
3 arrays exist and the output occurs in
accordance with the following.
o_u3SensorOutput[0]:
Controller judgment output 1
o_u3SensorOutput[1]:
Controller judgment output 2
o_u3SensorOutput[2]:
Controller judgment output 3
Stores the controller detected values.
15 arrays exist and each array stores the
detected value of the (n+1)th controller from
the parent device.