(2) Set the station number
The station number is configurable within the range of 1 to 120 in decimal.
The CC-Link IE Field network communication starts using the station number determined by the rotary switch setting as of
the time when the power is turned ON with the mode setting switch (SW1) OFF. Carefully note that if you change the
rotary switch setting after power-ON, the ERR.indicator (red) flashes.
Appendix 1.5.3
CC-Link parameter setup
Open GX Works3 to configure these settings.
Use the following steps to create PLC configuration data and then configure the CC-Link slaves.
(1) Creating a new project (common)
[Project] → [New]
Enter the series, model, and program language as shown in figure 1.5.3-1.
Change the model name depending on the actual system configuration.
Figure 1.5.3-1: Parameter settings ([New])
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
138/184
WUME-SCHG1IQRFB-1