Panasonic SC-HG1 Series Reference Manual page 111

For mitsubishi melsec iq-r series sequencer
Table of Contents

Advertisement

Item
Description of
functions
FB compilation
method
FB behavior
i_bEN input condition
When Execution Command (i_bEN) is turned ON, this FB executes alarm setting on the controller
specified by Set Controller (i_uSetController) in accordance with the values input to Alarm Delay
(i_uAlarmDelay) and Alarm Threshold (i_dAlarmThreshold). If Execution Command (i_bEN) is
turned ON with the Reset Flag (i_bReset) ON, the alarm setting for the specified controller is reset.
When Execution Command (i_bEN) is turned ON with Read Flag (i_bReadFlag) ON, however, the
Alarm Delay and Alarm Threshold values for all the connected controllers are output to Read Alarm
Delay (o_u15ReadAlarmDelay) and Read Alarm Threshold (o_d15ReadAlarmThreshold). In this
case, the various input values are ignored, and no setting takes place.
Macro type
Pulse execution type (multi-scan execution type)
None
SC-HG1 Series FB Library Reference Manual for Mitsubishi MELSEC iQ-R series Sequencer
Description
111/184
WUME-SCHG1IQRFB-1