Viessmann Vitovalor PT2 Installation And Service Instructions For Contractors page 70

Fuel cell based micro chp unit with integral gas condensing boiler and adjacent cylinder module natural gas version
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Measuring connection pressure (flow pressure)
D
B
Fig. 65
01. Switch off the gas condensing boiler ON/OFF
switch.
02. Fold down heat management unit
page 42.
03. Remove cover panel
04. Close gas shut-off valve
05. Loosen the screw in test connector
train, do not unscrew. Connect the pressure
gauge.
06. Open gas shut-off valve
07. Switch on the gas condensing boiler ON/OFF
switch.
08. Check the supply (flow) pressure.
Set value: 20 mbar (2.0 kPa)
If the set value is exceeded, take steps according
to the table on page 71.
Note
Use a suitable measuring device with a resolution
of at least 0.1 mbar (0.01 kPa) to check the supply
pressure.
70
A
. See
A
.
B
.
C
on the gas
D
.
C
(cont.)
C
09. Record the actual value in the report on
page 162.
10. Shut down the appliance and close the gas shut-
off valve. Remove the pressure gauge and tighten
the screw in test connector
11. Open the gas shut-off valve and start the appli-
ance.
Danger
Gas escaping from the test connector leads
to a risk of explosion.
Check test connector
12. Fit cover panel
.
D
for gas tightness.
D
.
B