Viessmann Vitovalor PT2 Installation And Service Instructions For Contractors page 120

Fuel cell based micro chp unit with integral gas condensing boiler and adjacent cylinder module natural gas version
Table of Contents

Advertisement

Troubleshooting
Fault messages on the gas condensing...
Control unit
System characteristics
message
F.303/C2F0
No power generation
F.304/C2F1
No power generation
120
(cont.)
Cause
Fault, stack voltage 1 (fuel
cell)
Fault, stack voltage 2 (fuel
cell)
Measures
Check balanced flue system for:
Flue gas recirculation
Leaks
Check ventilation air supply for:
Ingress of flue gas due to non-
compliance with chimney clear-
ances, e.g. by a solid fuel boil-
er
Outgassing/contamination in
the air supply system (e.g. sili-
cones, oils, paints, detergents,
deposits, etc.)
If faults recur, contact Viessmann
Technical Service.
Note
Fault message can only be reset
on the programming unit of the fuel
cell module.
Check balanced flue system for:
Flue gas recirculation
Leaks
Check ventilation air supply for:
Ingress of flue gas due to non-
compliance with chimney clear-
ances, e.g. by a solid fuel boil-
er
Outgassing/contamination in
the air supply system (e.g. sili-
cones, oils, paints, detergents,
deposits, etc.)
If faults recur, contact Viessmann
Technical Service.
Note
Fault message can only be reset
on the programming unit of the fuel
cell module.