Viessmann Vitovalor PT2 Installation And Service Instructions For Contractors page 103

Fuel cell based micro chp unit with integral gas condensing boiler and adjacent cylinder module natural gas version
Table of Contents

Advertisement

Fuel cell
(cont.)
600.0 "Reset fuel cell service counter"
Setting
OFF
ON
1097.0 "Export price, electrical energy per kWh"
Setting
1097.2 "Purchase price, electrical energy per kWh"
Setting
1098.0 "Gas price" per m
Setting
1411.0 "Clear maintenance messages"
Setting
No
Yes
1431.0 "CO2 factor gas per kWh"
Setting
1431.2 "CO2 factor power drawn per kWh"
Setting
0
1
0.043
0.001 to
5.0
0.258
0.001 to
5.0
3
0.053
0.001 to
5.0
0
1
0.23
0.01 to
10.00
800
0 to 1000
System configuration (parameters)
Explanations
Reset service counter once service has been carried
out.
Service counter reset
Reset the service counter.
Explanations
Export price for electrical energy per kWh
Export price in the delivered condition 0.043
Adjustable from 0.001 to 5.0
Explanations
Purchase price for electrical energy per kWh
Purchase price in the delivered condition 0.258
Adjustable from 0.001 to 5.0
Explanations
Gas price per m
3
Gas price in the delivered condition 0.053
Adjustable from 0.001 to 5.0
Explanations
Clear maintenance messages once maintenance has
been performed.
Maintenance messages are active (if present).
Clear maintenance messages once.
Explanations
CO
factor gas in kg/kWh
2
Factor in the delivered condition 230 g/kWh
Adjustable from 0.01 to 10.00
Explanations
CO
factor power drawn in g/kWh
2
Factor in the delivered condition 800 g/kWh
Adjustable from 0.00 to 10.00
10 to 10000 g/kWh
0 to 1000 g/kWh
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

F11tF19tF25tF32t

Table of Contents