Installation sequence
Electrical connections

Connections on the M2IO electronics module of the cylinder module

The mains connection and PlusBus wiring chamber of
accessories takes place on the M2IO electronics mod-
ule of the cylinder module.
74
74
Fig. 40
TS1
A Cylinder temperature sensor top (connected
%
in the delivered condition)
TS2
B Cylinder temperature sensor bottom (con-
%
nected in the delivered condition)
TS4
Return temperature sensor (connected in
aJ
the delivered condition)
P1
sA
Cylinder loading pump (connected in the
delivered condition)
P2
DHW circulation pump
sK
Power supply via gas condensing module
Power supply for further accessories
A
PlusBus connection, further accessories
jF
46
(cont.)
TS1
5A
TS2
5B
P2
TS4 17
28
P1
40A
40